https://www.dianzimai.com/

Circulator DH9-4-8G-1557

In Stock 15
Frequency4000~8000MHz, Forward Power10W, SMA
$ 40
Delivery Time : 1-3 Day(WorkDay)
Terms: Ex Work from Chengdu warehouse, minimum order amount US$200. The product is produced by COM-MW Technology Co.,Ltd and sold by Dianzibuy Inc.

MOQ : 1
Attention: The online trading belongs to commercial activities, the final transaction price might be lower than tag price, subject to automatically system calculating; The price is competitive, product fully tested and qualified, we will offer certificate of conformity, no test report.

Product features

Broadband, high-power.

Main specifications

ParametersMinTypicalMaxUnits
Frequency4000~8000MHz
IL0.5dB
Isolation15dB
VSWR1.4

Other parameters

Forward Power10W Design assurance
DirectionAnticlockwise
ConnectorSMA-K
Impedance50Ω
Work Temp.-30~+70℃ Design assurance

Typical test data

Frequency(MHz)S11 VSWRS21 loss dBS12 ISO dBS22 VSWR
35001.45-0.7-14.451.42
38571.28-0.5-18.081.28
42141.15-0.37-24.431.15
45711.09-0.31-36.211.04
49291.16-0.3-26.71.1
52861.24-0.34-22.091.18
56431.28-0.38-20.561.22
60001.31-0.41-20.521.26
63571.32-0.4-21.851.29
67141.3-0.36-24.311.29
70711.26-0.33-27.151.25
74291.23-0.32-29.381.19
77861.23-0.32-31.691.16
81431.34-0.5-24.921.3
85003.61-3.94-10.724.05

Reference picture

Configuration(mm)

Typical test curve

Note

The installation surface is flat, and the grounding is good. The isolator and circulator are unidirectional devices, so pay attention to the input and output ports. Isolators and circulator are magnetic devices, Please use stainless steel screws to fix them, It is forbidden to use steel screws, It is forbidden to install the devices on the steel shell. They are installed in the same assembly with other devices with permanent magnets or other isolators, Please keep the distance between the devices greater than 1cm, otherwise the electrical performance of the product may be affected. If the overall temperature of the product is greater than 100 ℃, please negotiate with us before placing an order. Clean the surface of the product, do not immerse the product in cleaning solution for cleaning. The isolator and circulator should be stored separately for a long time, Please store them in a moisture-proof box with humidity less than 25%.